Табела со спецификации за FTXP-P / RXP-N

FTXP20P5V1B / RXP20N5V1B FTXP25P5V1B / RXP20N5V1B FTXP35P5V1B / RXP20N5V1B FTXP60P2V1B / RXP60N5V1B FTXP71P2V1B / RXP71N5V1B
Outdoor unit RXP20N5V1B RXP25N5V1B RXP35N5V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.7 2.3
  Nom. kW 2.00 2.50 3.50 6.0 7.1
  Max. kW 2.6 3.0 4.0 7.0 7.3
Heating capacity Min. kW 1.30 1.30 1.30 1.7 2.3
  Nom. kW 2.50 3.00 4.00 7.0 8.2
  Max. kW 3.50 4.00 4.80 8.0 9.0
Nominal efficiency EER   3.75 3.75 3.48 3.29 2.64
  COP   4.77 4.36 4.02 3.63 3.19
  Annual energy consumption kWh       912 1345
  Energy labeling Directive Cooling   A A A A D
    Heating   A A A A D
Space cooling Energy efficiency class   A++ A++ A++ A++ A++
  Capacity Pdesign kW 2.00 2.50 3.50 6.0 7.1
  SEER   7.20 7.20 7.20 6.82 6.20
  Annual energy consumption kWh/a 97 121 170 308 401
Space heating (Average climate) Energy efficiency class   A++ A++ A++ A+ A+
  Capacity Pdesign kW 2.20 2.40 2.80 4.80 6.20
  SCOP/A   4.65 4.61 4.64 4.10 4.01
  Pdh Heating capacity at -10° kW 1.99 2.09 2.35 3.29 4.24
  Annual energy consumption kWh/a 663 728 845 1638 2166
Опсег на енергетска ефикасност A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data