Табела со спецификации за FTXP-N / RXP-N9

FTXP20N5V1B / RXP20N5V1B9 FTXP25N5V1B / RXP25N5V1B9 FTXP35N5V1B / RXP35N5V1B9 FTXP50N2V1B / RXP50N5V1B9 FTXP60N2V1B / RXP60N5V1B9 FTXP71N2V1B / RXP71N5V1B9
Outdoor unit RXP20N5V1B9 RXP25N5V1B9 RXP35N5V1B9
Cooling capacity Min. kW 1.3 1.3 1.3 1.7 1.7 2.3
  Nom. kW 2.00 2.50 3.50 5.0 6.0 7.1
  Max. kW 2.6 3.0 4.0 6.0 7.0 7.3
Heating capacity Min. kW 1.30 1.30 1.30 1.7 1.7 2.3
  Nom. kW 2.50 3.00 4.00 6.0 7.0 8.2
  Max. kW 3.50 4.00 4.80 7.7 8.0 9.0
Nominal efficiency EER   3.75 3.75 3.26 3.61 3.29 2.64
  COP   4.77 4.36 4.02 3.80 3.63 3.19
  Annual energy consumption kWh       693 912 1345
  Energy labeling Directive Cooling   A A A A A D
    Heating   A A A A A D
Space cooling Energy efficiency class   A++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 2.00 2.50 3.50 5.0 6.0 7.1
  SEER   7.20 7.20 7.20 7.30 6.82 6.20
  Annual energy consumption kWh/a 97 121 170 240 308 401
Space heating (Average climate) Energy efficiency class   A++ A++ A++ A+ A+ A+
  Capacity Pdesign kW 2.20 2.40 2.80 4.60 4.80 6.20
  SCOP/A   4.65 4.61 4.64 4.40 4.10 4.01
  Pdh Heating capacity at -10° kW 1.99 2.09 2.35 3.15 3.29 4.24
  Annual energy consumption kWh/a 663 728 845 1463 1638 2166
Опсег на енергетска ефикасност A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data