| FTXM25R5V1B / FTXM25R5V1B / 2MXM50A2V1B8 | FTXM25R2V1B / FTXM25R2V1B / 2MXM50A2V1B8 | FTXM35R5V1B / FTXM35R5V1B / 2MXM68A2V1B8 | FTXM35R2V1B / FTXM35R2V1B / 2MXM68A2V1B8 | FTXM20R5V1B / FTXM50R2V1B / 2MXM68A2V1B8 | FTXM20R2V1B / FTXM50R2V1B / 2MXM68A2V1B8 | FTXM25R2V1B / FTXM42R2V1B / 2MXM68A2V1B8 | FTXM25R5V1B / FTXM42R5V1B / 2MXM68A2V1B8 | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.00 | 5.00 | 6.8 | 6.8 | 6.8 | 6.8 | 6.7 | 6.7 | |
| Heating capacity | Nom. | kW | 5.60 | 5.60 | 8.60 | 8.60 | 8.60 | 8.60 | 8.30 | 8.30 | |
| Nominal efficiency | EER | 4.01 | 4.01 | 3.94 | 3.94 | 3.59 | 3.59 | 3.74 | 3.74 | ||
| COP | 4.08 | 4.08 | 3.81 | 3.81 | 3.82 | 3.82 | 3.95 | 3.95 | |||
| Annual energy consumption | kWh | 623 | 623 | 863 | 863 | 947 | 947 | 896 | 896 | ||
| Energy labeling Directive | Cooling | A | A | ||||||||
| Heating | A | A | |||||||||
| Space cooling | Energy efficiency class | A+++ | A+++ | A++ | A++ | A++ | A++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 5.00 | 5.00 | 6.80 | 6.80 | 6.80 | 6.80 | 6.70 | 6.70 | |
| SEER | 8.53 | 8.53 | 6.97 | 6.97 | 6.75 | 6.75 | 6.94 | 6.94 | |||
| Annual energy consumption | kWh/a | 205 | 205 | 342 | 342 | 353 | 353 | 338 | 338 | ||
| Space heating (Average climate) | Energy efficiency class | A++ | A++ | A+ | A+ | A | A | A | A | ||
| Capacity | Pdesign | kW | 4.20 | 4.20 | 4.80 | 4.80 | 4.50 | 4.50 | 4.30 | 4.30 | |
| SCOP/A | 4.61 | 4.61 | 4.00 | 4.00 | 3.90 | 3.90 | 3.86 | 3.86 | |||
| Pdh Heating capacity at -10° | kW | 3.20 | 3.20 | 3.73 | 3.73 | 3.55 | 3.55 | 3.41 | 3.41 | ||
| Annual energy consumption | kWh/a | 1,275 | 1,275 | 1,680 | 1,680 | 1,614 | 1,614 | 1,560 | 1,560 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||