FTXM20N2V1B / FTXM35N2V1B / 2MXM40A2V1B FTXM20N2V1B / FTXM20N2V1B / 2MXM40A2V1B FTXM20N2V1B / FTXM25N2V1B / 2MXM40A2V1B FTXM25N2V1B / FTXM25N2V1B / 2MXM40A2V1B FTXM25N2V1B / FTXM35N2V1B / 2MXM40A2V1B FTXM20N2V1B / FTXM20N2V1B / 2MXM50A2V1B FTXM20N2V1B / FTXM35N2V1B / 2MXM50A2V1B FTXM20N2V1B / FTXM50N2V1B / 2MXM50A2V1B FTXM35N2V1B / FTXM35N2V1B / 2MXM50A2V1B FTXM35N2V1B / FTXM50N2V1B / 2MXM50A2V1B FTXM20N2V1B / FTXM25N2V1B / 2MXM50A2V1B FTXM20N2V1B / FTXM42N2V1B / 2MXM50A2V1B FTXM25N2V1B / FTXM25N2V1B / 2MXM50A2V1B FTXM25N2V1B / FTXM35N2V1B / 2MXM50A2V1B FTXM25N2V1B / FTXM42N2V1B / 2MXM50A2V1B FTXM25N2V1B / FTXM50N2V1B / 2MXM50A2V1B FTXM35N2V1B / FTXM42N2V1B / 2MXM50A2V1B FTXM42N2V1B / FTXM42N2V1B / 2MXM50A2V1B FTXM20N2V1B / FTXM50N2V1B / 2MXM68A2V1B FTXM35N2V1B / FTXM35N2V1B / 2MXM68A2V1B FTXM25N2V1B / FTXM42N2V1B / 2MXM68A2V1B
Cooling capacity Nom. kW 4.00         4.00 5.00 5.00 5.00 5.00
Space cooling SEER   8.19         8.71 8.54 8.51 8.57 8.52
  Annual energy consumption kWh/a 171         161 205 206 205 206
  Capacity Pdesign kW 4.00         4.00 5.00 5.00 5.00 5.00
  Energy efficiency class   A++         A+++ A+++ A+++ A+++ A+++
Space heating (Average climate) Capacity Pdesign kW 3.20         4.00 4.20 4.20 4.20 4.20
  SCOP/A   4.60         4.61 4.61 4.68 4.66 4.75
  Energy efficiency class   A++         A++ A++ A++ A++ A++
  Pdh Heating capacity at -10° kW 2.58         3.27 3.40 3.51 3.42 3.54
  Annual energy consumption kWh/a 974         1,214 1,275 1,255 1,262 1,238
Nominal efficiency Annual energy consumption kWh 476         471 619 608 608 598
  EER   4.20         4.25 4.04 4.11 4.11 4.18
  COP   4.41         4.09 4.12 4.15 4.01 3.94
  Energy labeling Directive Cooling   A         A A A A A
    Heating   A         A A A A A
Heating capacity Nom. kW 4.20         5.20 5.60 5.60 5.60 5.60
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data
Cooling capacity Nom. kW   4.00 4.00 4.00 4.00           4.50 5.00 5.00 5.00 5.00 5.00 5.00 5.00 6.8 6.8 6.7
Heating capacity Nom. kW   4.20 4.20 4.20 4.20           5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 8.60 8.60 8.30
Nominal efficiency EER     4.30 4.16 4.18 4.24           4.21 4.07 4.01 4.06 4.09 4.13 4.14 4.16 3.59 3.94 3.74
  COP     4.28 4.32 4.37 4.46           4.10 4.13 4.08 4.05 4.03 3.98 4.00 3.98 3.82 3.81 3.95
  Annual energy consumption kWh   465 481 478 472           534 614 623 616 611 605 604 601 947 863 896
  Energy labeling Directive Cooling     A A A A           A A A A A A A A
    Heating     A A A A           A A A A A A A A
Space cooling Energy efficiency class     A+++ A+++ A++ A++           A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A++
  Capacity Pdesign kW   4.00 4.00 4.00 4.00           4.50 5.00 5.00 5.00 5.00 5.00 5.00 5.00 6.80 6.80 6.70
  SEER     8.53 8.50 8.36 8.11           8.67 8.54 8.53 8.56 8.58 8.52 8.60 8.56 6.75 6.97 6.94
  Annual energy consumption kWh/a   164 165 168 173           182 205 205 205 204 206 204 205 353 342 338
Space heating (Average climate) Energy efficiency class     A++ A++ A++ A++           A++ A++ A++ A++ A++ A++ A++ A++ A A+ A
  Capacity Pdesign kW   3.20 3.20 3.20 3.20           4.10 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.50 4.80 4.30
  SCOP/A     4.64 4.60 4.60 4.61           4.61 4.63 4.61 4.62 4.65 4.71 4.67 4.70 3.90 4.00 3.86
  Pdh Heating capacity at -10° kW   2.55 2.56 2.57 2.59           3.33 3.41 3.20 3.41 3.42 3.53 3.43 3.44 3.55 3.73 3.41
  Annual energy consumption kWh/a   966 973 974 971           1244 1268 1275 1272 1265 1249 1258 1251 1614 1680 1560
Опсег на енергетска ефикасност   A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D           A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D