Табела со спецификации за FTXM-B / RXM-R9

FTXM20B2V1B / RXM20R5V1B9 FTXM20B5V1B / RXM20R5V1B9 FTXM25B2V1B / RXM25R5V1B9 FTXM25B5V1B / RXM25R5V1B9 FTXM35B2V1B / RXM35R5V1B9 FTXM35B5V1B / RXM35R5V1B9
Cooling capacity Min. kW 1.30 1.30 1.30 1.30 1.40 1.40
  Nom. kW 2.00 2.00 2.50 2.50 3.40 3.40
  Max. kW 2.60 2.60 3.20 3.20 4.00 4.00
Heating capacity Min. kW 1.30 1.30 1.30 1.30 1.40 1.40
  Nom. kW 2.50 2.50 2.80 2.80 4.00 4.00
  Max. kW 3.50 3.50 4.70 4.70 5.20 5.20
Nominal efficiency EER   4.57 4.57 4.50 4.50 4.23 4.23
  COP   5.00 5.00 5.00 5.00 4.04 4.04
  Annual energy consumption kWh 219 219 278 278 402 402
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++
  Capacity Pdesign kW 2.00 2.00 2.50 2.50 3.40 3.40
  SEER   8.65 8.65 8.65 8.65 8.65 8.65
  Annual energy consumption kWh/a 81 81 101 101 137 137
Space heating (Average climate) Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++
  Capacity Pdesign kW 2.30 2.30 2.40 2.40 2.50 2.50
  SCOP/A   5.10 5.10 5.10 5.10 5.10 5.10
  Pdh Heating capacity at -10° kW 2.24 2.24 2.30 2.30 2.35 2.35
  Annual energy consumption kWh/a 631 631 659 659 686 686
Опсег на енергетска ефикасност A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.