| FTXJ20A2V1BB9 / RXJ20A5V1B | FTXJ25A2V1BB9 / RXJ25A5V1B | FTXJ35A2V1BB9 / RXJ35A5V1B | FTXJ42A2V1BB9 / RXJ42A2V1B | FTXJ50A2V1BB9 / RXJ50A2V1B | ||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.7 | 1.7 | |
| Nom. | kW | 2 | 2.5 | 3.4 | 4.2 | 5 | ||
| Max. | kW | 2.6 | 3.2 | 4 | 5 | 5.3 | ||
| Heating capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.7 | 1.7 | |
| Nom. | kW | 2.5 | 2.8 | 4 | 5.4 | 5.8 | ||
| Max. | kW | 3.5 | 4.7 | 5.2 | 6 | 6.5 | ||
| Nominal efficiency | EER | 4.7 | 4.46 | 4.37 | 3.99 | 3.68 | ||
| COP | 5 | 5 | 4.04 | 4.12 | 4 | |||
| Annual energy consumption | kWh | 213 | 280 | 389 | 526 | 679 | ||
| Energy labeling Directive | Cooling | A | A | A | A | A | ||
| Heating | A | A | A | A | A | |||
| Space cooling | Energy efficiency class | A+++ | A+++ | A+++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2 | 2.5 | 3.4 | 4.2 | 5 | |
| SEER | 8.75 | 8.74 | 8.73 | 7.5 | 7.33 | |||
| Annual energy consumption | kWh/a | 80 | 100 | 136 | 196 | 239 | ||
| Space heating (Average climate) | Energy efficiency class | A+++ | A+++ | A+++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2.4 | 2.45 | 2.5 | 3.8 | 4 | |
| SCOP/A | 5.15 | 5.15 | 5.15 | 4.6 | 4.6 | |||
| Pdh Heating capacity at -10° | kW | 2.02 | 2.07 | 2.11 | 3.26 | 3.44 | ||
| Annual energy consumption | kWh/a | 652 | 666 | 680 | 1,156 | 1,218 | ||
| Notes | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||