| FTXF20E5V1B / RXF20C5V1B | FTXF25E5V1B / RXF25C5V1B | FTXF35E5V1B / RXF35C5V1B | FTXF42E5V1B / RXF42C5V1B | ||||
|---|---|---|---|---|---|---|---|
| Outdoor unit | RXF20C5V1B | RXF25C5V1B | RXF35C5V1B | RXF42C5V1B | |||
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.3 | 1.4 | |
| Nom. | kW | 2 | 2.5 | 3.3 | 4.2 | ||
| Max. | kW | 2.4 | 2.8 | 3.8 | 4.3 | ||
| Heating capacity | Min. | kW | 1.3 | 1.3 | 1.3 | 1.4 | |
| Nom. | kW | 2.4 | 2.8 | 3.5 | 4.6 | ||
| Max. | kW | 3.3 | 3.7 | 4.4 | 5 | ||
| Nominal efficiency | EER | 3.38 | 3.24 | 3.3 | 3.3 | ||
| COP | 3.75 | 3.73 | 3.72 | 3.71 | |||
| Energy labeling Directive | Cooling | A | A | A | A | ||
| Heating | A | A | A | A | |||
| Space cooling | Energy efficiency class | A++ | A++ | A++ | A++ | ||
| Capacity | Pdesign | kW | 2 | 2.5 | 3.5 | 4.2 | |
| SEER | 6.22 | 6.22 | 6.22 | 6.5 | |||
| Annual energy consumption | kWh/a | 113 | 141 | 197 | 226 | ||
| Space heating (Average climate) | Energy efficiency class | A+ | A+ | A+ | A+ | ||
| Capacity | Pdesign | kW | 2.2 | 2.4 | 2.6 | 3.3 | |
| SCOP/A | 4.11 | 4.11 | 4.11 | 4.3 | |||
| Pdh Heating capacity at -10° | kW | 1.91 | 2 | 2.22 | 2.61 | ||
| Annual energy consumption | kWh/a | 749 | 817 | 885 | 1075 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | ||||
| (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | ||||