Табела со спецификации за EPBXU10A4V / EPSK08-10AW1

EPBXU10AJ4V / EPSK08ARW1 EPBXU10AF4V / EPSK08ARW1 EPBXU10AJ4V / EPSK10ARW1 EPBXU10AF4V / EPSK10ARW1
Heating capacity Nom. kW 7.62 (1) 7.62 (1) 8.11 (1) 8.11 (1)
Cooling capacity Nom. kW 6.89 (3), 6.37 (4) 6.89 (2), 6.37 (3) 7.84 (3), 6.37 (4) 7.84 (2), 6.37 (4)
Power input Heating Nom. kW 1.52 (1) 1.52 (1) 1.64 (1) 1.64 (1)
  Cooling Nom. kW 1.85 (3), 1.13 (4) 1.85 (2), 1.13 (3) 2.17 (3), 1.13 (4) 2.17 (2), 1.13 (4)
COP 5.01 (1) 5.01 (1) 4.94 (1) 4.94 (1)
EER 3.73 (3), 5.63 (4) 3.73 (2), 5.63 (3) 3.62 (3), 5.63 (4) 3.62 (2), 5.63 (4)
Space heating Average climate water outlet 55°C General SCOP   3.94 3.94 3.99 3.99
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++
  Average climate water outlet 35°C General SCOP   5.14 5.14 5.14 5.14
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++
Опсег на енергетска ефикасност Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F
Notes (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (2) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (2) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (2) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB   (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511   (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511