Табела со спецификации за ELVX-E9W / ERRA08-12EV3

ELVX12S18EJ9W / ERRA08EAV3 ELVX12S23EJ9W / ERRA08EAV3 ELVX12S18EJ9W / ERRA10EAV3 ELVX12S23EJ9W / ERRA10EAV3 ELVX12S18EJ9W / ERRA12EAV3 ELVX12S23EJ9W / ERRA12EAV3
Heating capacity Min. kW 3.45 3.45 3.45 3.45 3.45 3.45
  Nom. kW 6.17 6.17 6.17 6.17 6.17 6.17
  Max. kW 7.95 7.95 9.25 9.25 9.97 9.97
Cooling capacity Nom. kW 6.81, 6.47 6.81, 6.47 7.97, 6.47 7.97, 6.47 8.62, 6.47 8.62, 6.47
Power input Heating Min. kW 0.72 0.72 0.72 0.72 0.72 0.72
    Nom. kW 1.25 1.25 1.25 1.25 1.25 1.25
    Max. kW 1.69 1.69 2.04 2.04 2.28 2.28
  Cooling Nom. kW 2.15, 1.16 2.15, 1.16 2.66, 1.16 2.66, 1.16 2.96, 1.16 2.96, 1.16
  Domestic hot water from 10°C to 50°C Nom. kWh 2.63 3.19 2.63 3.19 2.63 3.19
Heat up time from 10°C to 50°C hr 1 ч 51 мин 2 ч 10 мин 1 ч 51 мин 2 ч 10 мин 1 ч 51 мин 2 ч 10 мин
COP 4.92 4.92 4.92 4.92 4.92 4.92
EER 3.17, 5.56 3.17, 5.56 3.00, 5.56 3.00, 5.56 2.91, 5.56 2.91, 5.56
Domestic hot water heating General Declared load profile   L L L L L L
  Average climate Water heating energy efficiency class   A+ A+ A+ A+ A+ A+
Space heating Average climate water outlet 55°C General SCOP   3.37 3.37 3.38 3.38 3.47 3.47
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.79 4.79 4.82 4.82 4.82 4.82
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++
Notes (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511
  (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина