ELVH12S18EJ6V / ERRA08EAV37 ELVH12S23EJ6V / ERRA08EAV37 ELVH12S18EJ6V / ERRA10EAV37 ELVH12S23EJ6V / ERRA10EAV37 ELVH12S18EJ6V / ERRA12EAV37 ELVH12S23EJ6V / ERRA12EAV37
Heating capacity Min. kW 3.45 (1) 3.45 (1) 3.45 (1) 3.45 (1) 3.45 (1) 3.45 (1)
  Nom. kW 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2)
  Max. kW 7.95 (1) 7.95 (1) 9.25 (1) 9.25 (1) 9.97 (1) 9.97 (1)
Power input Heating Min. kW 0.72 (5) 0.72 (5) 0.72 (5) 0.72 (5) 0.72 (5) 0.72 (5)
    Nom. kW 1.25 (2) 1.25 (2) 1.25 (2) 1.25 (2) 1.25 (2) 1.25 (2)
    Max. kW 1.69 (5) 1.69 (5) 2.04 (5) 2.04 (5) 2.28 (5) 2.28 (5)
  Domestic hot water from 10°C to 50°C Nom. kWh 2.63 (6) 3.19 (6) 2.63 (6) 3.19 (6) 2.63 (6) 3.19 (6)
Heat up time from 10°C to 50°C hr 1h 51m 2 ч 10 мин 1h 51m 2 ч 10 мин 1h 51m 2 ч 10 мин
COP 4.92 (2) 4.92 (2) 4.92 (2) 4.92 (2) 4.92 (2) 4.92 (2)
Domestic hot water heating General Declared load profile   L L L L L L
  Average climate Water heating energy efficiency class   A+ A+ A+ A+ A+ A+
Space heating Average climate water outlet 55°C General SCOP   3.34 3.34 3.34 3.34 3.44 3.44
      Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.69 4.69 4.71 4.71 4.71 4.71
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++
Опсег на енергетска ефикасност Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F
Notes (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C (1) - Капацитет според стандардот EN14511 и важечки за опсег на топла вода dT = 3~8°C при Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511 (5) - Напојувањето со струја е вкупно напојување на внатрешните и надворешните единици, заедно со циркуларната пумпа; според EN14511
  (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) со пумпа при полна брзина