Табела со спецификации за CHVX-A

CHVX07S18AJ4V CHVX07S18AJ9W CHVX07S23AJ9W CHVX07S23AJ4V
Куќиште Боја   White + Black White + Black White + Black White + Black
  Материјал   Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal
Димензии Единица Висина mm 1655 1655 1855 1855
    Ширина mm 597 597 597 597
    Длабочина mm 634 634 634 634
Тежина Единица kg 113 113 121 121
PED Категорија   See note 1 See note 1 See note 1 See note 1
Sound power level Nom. dBA 44.0 (5) 44.0 (5) 44.0 (5) 44.0 (5)
Sound pressure level Nom. dBA 30.0 (5) 30.0 (5) 30.0 (5) 30.0 (5)
Operation range Heating Water side Min. °C 18 (6) 18 (6) 18 (6) 18 (6)
      Max. °C 55 (6) 55 (6) 55 (6) 55 (6)
  Cooling Ambient Min. °CDB 10 (6) 10 (6) 10 (6) 10 (6)
    Water side Min. °C 18 (6) 18 (6) 18 (6) 18 (6)
      Max. °C 22 (6) 22 (6) 22 (6) 22 (6)
Напојување со струја Име   See note 7 See note 7 See note 7 See note 7
Electric heater Power supply Name   4V 9W 9W 4V
    Phase   1~ / 3~ 3~ 3~ 1~ / 3~
    Frequency Hz 50 50 50 50
    Voltage V 230/400 400 400 230/400
  Recommended fuses A 0.000 (8) 0.000 (8) 0.000 (8) 0.000 (8)
Notes (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f (1) - Assembly ≤ category I: excluded from 2014/68/EU due to article 1, 2f
  (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (3) - Базирано на dT од 45 K (3) - Базирано на dT од 45 K (3) - Базирано на dT од 45 K (3) - Базирано на dT од 45 K
  (4) - Including piping + PHE + back-up heater; excluding expansion vessel (4) - Including piping + PHE + back-up heater; excluding expansion vessel (4) - Including piping + PHE + back-up heater; excluding expansion vessel (4) - Including piping + PHE + back-up heater; excluding expansion vessel
  (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. (5) - Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°.
  (6) - For more details, see operation range drawing (6) - For more details, see operation range drawing (6) - For more details, see operation range drawing (6) - For more details, see operation range drawing
  (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (7) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply.
  (8) - Погледнете ја шемата за електрична инсталација и прирачникот за инсталирање за точно препорачани осигурувачи во зависност од напојувањето со струја и поврзаната електрична мрежа (8) - Погледнете ја шемата за електрична инсталација и прирачникот за инсталирање за точно препорачани осигурувачи во зависност од напојувањето со струја и поврзаната електрична мрежа (8) - Погледнете ја шемата за електрична инсталација и прирачникот за инсталирање за точно препорачани осигурувачи во зависност од напојувањето со струја и поврзаната електрична мрежа (8) - Погледнете ја шемата за електрична инсталација и прирачникот за инсталирање за точно препорачани осигурувачи во зависност од напојувањето со струја и поврзаната електрична мрежа