Табела со спецификации за ATXF-J / ARXF-E

ATXF20J5V1B / ARXF20E5V1B ATXF25J5V1B / ARXF25E5V1B ATXF35J5V1B / ARXF35E5V1B ATXF42J5V1B / ARXF42E5V1B
Outdoor unit ARXF20E5V1B ARXF25E5V1B ARXF35E5V1B ARXF42E5V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.4
  Nom. kW 2.00 2.50 3.30 4.20
  Max. kW 2.4 2.8 3.8 4.3
Heating capacity Min. kW 1.30 1.30 1.30 1.40
  Nom. kW 2.40 2.80 3.50 4.60
  Max. kW 3.30 3.70 4.40 5.00
Nominal efficiency EER   3.33 3.24 3.27 3.27
  COP   3.75 3.73 3.72 3.71
  Annual energy consumption kWh 109 137 191 228
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Space cooling Energy efficiency class   A++ A++ A++ A++
  Capacity Pdesign kW 2.00 2.50 3.50 4.20
  SEER   6.40 6.40 6.40 6.45
  Annual energy consumption kWh/a 109 137 191 228
Space heating (Average climate) Energy efficiency class   A+ A+ A+ A+
  Capacity Pdesign kW 2.20 2.40 2.60 3.30
  SCOP/A   4.16 4.10 4.10 4.25
  Pdh Heating capacity at -10° kW 1.86 1.97 2.21 2.61
  Annual energy consumption kWh/a 740 819 889 1088
Опсег на енергетска ефикасност A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data