Specifications Table for UATYA-BFC3Y1

UATYA25BFC3Y1 UATYA30BFC3Y1 UATYA40BFC3Y1 UATYA50BFC3Y1 UATYA60BFC3Y1 UATYA70BFC3Y1 UATYA80BFC3Y1 UATYA90BFC3Y1 UATYA100BFC3Y1 UATYA110BFC3Y1 UATYA120BFC3Y1 UATYA140BFC3Y1 UATYA150BFC3Y1 UATYA160BFC3Y1 UATYA180BFC3Y1 UATYA190BFC3Y1
Cooling capacity Nom. kW 25.8 (1) 33.4 (1) 38.7 (1) 45.7 (1) 58.8 (1) 65.3 (1) 74.8 (1) 89.8 (1) 95.8 (1) 108.9 (1) 115.0 (1) 133.4 (1) 144.7 (1) 154.6 (1) 171.9 (1) 187.0 (1)
  With 30% fresh air kW 27.8 (1) 36.1 (1) 42.5 (1) 49.6 (1) 63.7 (1) 70.5 (1) 81.3 (1) 96.8 (1) 104.3 (1) 118.0 (1) 124.5 (1) 145.6 (1) 156.8 (1) 168.3 (1) 186.5 (1) 204.4 (1)
Heating capacity Nom. kW 25.3 (2) 31.1 (2) 36.3 (2) 46.2 (2) 55.1 (2) 64.9 (2) 68.5 (2) 84.2 (2) 92.8 (2) 101.5 (2) 108.0 (2) 123.1 (2) 136.4 (2) 147.1 (2) 157.1 (2) 176.9 (2)
  With 30% fresh air kW 26.0 (2) 32.4 (2) 38.3 (2) 47.7 (2) 57.1 (2) 68.6 (2) 71.6 (2) 87.2 (2) 97.9 (2) 107.0 (2) 112.3 (2) 132.0 (2) 147.5 (2) 160.0 (2) 173.5 (2) 191.6 (2)
Power input Cooling Nom. kW 9.1 (1) 10.8 (1) 12.7 (1) 15.4 (1) 18.8 (1) 22.4 (1) 24.2 (1) 29.4 (1) 32.3 (1) 36.4 (1) 39.5 (1) 42.5 (1) 47.9 (1) 50.7 (1) 56.1 (1) 62.9 (1)
  Heating Nom. kW 7.8 (2) 9.4 (2) 11.1 (2) 14.2 (2) 16.9 (2) 20.2 (2) 20.3 (2) 26.1 (2) 29.0 (2) 30.3 (2) 33.2 (2) 35.8 (2) 40.9 (2) 45.1 (2) 47.2 (2) 54.2 (2)
EER 2.83 (1), 2.96 (3) 3.09 (1), 3.20 (3) 3.06 (1), 3.27 (3) 2.96 (1), 3.12 (3) 3.12 (1), 3.23 (3) 2.92 (1), 3.00 (3) 3.09 (1), 3.21 (3) 3.06 (1), 3.22 (3) 2.97 (1), 3.14 (3) 2.99 (1), 3.11 (3) 2.91 (1), 3.01 (3) 3.14 (1), 3.26 (3) 3.02 (1), 3.14 (3) 3.05 (1), 3.18 (3) 3.07 (1), 3.21 (3) 2.97 (1), 3.14 (3)
COP 3.22 (2), 3.38 (3) 3.31 (2), 3.48 (3) 3.26 (2), 3.51 (3) 3.24 (2), 3.46 (3) 3.25 (2), 3.40 (3) 3.21 (2), 3.39 (3) 3.37 (2), 3.56 (3) 3.22 (2), 3.45 (3) 3.20 (2), 3.42 (3) 3.35 (2), 3.57 (3) 3.25 (2), 3.40 (3) 3.44 (2), 3.62 (3) 3.33 (2), 3.57 (3) 3.26 (2), 3.49 (3) 3.33 (2), 3.63 (3) 3.27 (2), 3.50 (3)
Space cooling Capacity Pdesign kW 25.8 33.4 38.7 45.7 58.8 65.3 74.8 89.8 95.8 108.9 115.0 133.4 144.7 154.6 171.9 187.0
Space heating (Average climate) Capacity Pdesign kW 25.3 31.1 36.3 46.2 55.1 64.9 68.5 84.2 92.8 101.5 108.0 123.1 136.4 147.1 157.1 176.9
Evaporator Supply side Fan High ESP Pa 425 (5) 727 (5) 510 (5) 439 (5) 629 (5) 410 (5) 526 (5) 493 (5) 463 (5) 427 (5) 394 (5) 441 (5) 416 (5) 388 (5) 340 (5) 310 (5)
      Nominal ESP Pa 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5)
  Return side Fan High ESP Pa 461 (5) 352 (5) 561 (5) 519 (5) 426 (5) 474 (5) 596 (5) 543 (5) 519 (5) 483 (5) 438 (5) 324 (5) 445 (5) 353 (5) 497 (5) 428 (5)
      Nominal ESP Pa 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5) 300 (5)
  Fresh air Ratio Standard % 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
      In free cooling % 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
Condenser Refrigerant GWP   675 675 675 675 675 675 675 675 675 675 675 675 675 675 675 675
    Charge TCO2Eq 4,725 6,750 8,100 10,125 12,150 12,150 15,525 16,200 18,900 20,250 24,300 25,650 25,650 31,050 33,750 33,750
Dimensions Unit Height Mm 1,924 1,924 2,374 2,374 1,924 1,924 2,374 2,374 2,374 2,374 2,374 2,374 2,374 2,374 2,374 2,374
    Width Mm 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250 2,250
    Depth Mm 3,514 3,514 3,514 3,514 6,317 6,317 6,317 6,317 6,317 6,317 6,317 7,117 7,117 7,117 7,117 7,117
Weight Unit kg 1,166 1,196 1,310 1,329 1,996 2,094 2,336 2,382 2,452 2,548 2,558 3,024 3,035 3,074 3,192 3,271
Sound pressure level Cooling dBA 63.9 (6) 66.0 (6) 68.0 (6) 67.3 (6) 69.0 (6) 68.1 (6) 72.6 (6) 68.7 (6) 69.9 (6) 70.6 (6) 74.2 (6) 68.3 (6) 68.3 (6) 68.7 (6) 69.1 (6) 70.0 (6)
Sound power level Cooling dBA 82.2 (7) 84.3 (7) 86.8 (7) 86.1 (7) 88.5 (7) 87.5 (7) 92.5 (7) 88.6 (7) 89.8 (7) 90.5 (7) 94.1 (7) 88.6 (7) 88.6 (7) 89.0 (7) 89.3 (7) 90.2 (7)
Power supply Name   400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5% 400/3/50±5%
  Phase   3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~
  Frequency Hz 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
  Voltage V 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400
Current Recommended fuses A 25 40 40 50 50 63 80 100 100 100 100 160 160 160 200 200
Notes (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018 (1) - Conditions for calculation: Ambient air 27°C DB, 19°C WB; External air 35°C DB, 24°C WB. 100% recirculating air; calculated according to EN 14511/2018
  (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018 (2) - Conditions for calculation: Ambient air 20°C DB, 15°C WB; External air 7°C DB, 6°C WB. 100% recirculating air; calculated according to EN 14511/2018
  (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air (3) - With 30% fresh air
  (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019 (4) - Calculated according to EN 14825/2019
  (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters. (5) - Value refers to unit at nominal airflow, delivered with no accessories and with only G4 filters.
  (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level (6) - Average sound pressure level, at 1 meter from the unit, in free field on a reflective surface. Not binding value derived from the sound power level
  (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version (7) - Sound power level in free field calculated according to standard ISO 3744. Values refer only to the base unit version