Specifications Table for FTXM-M / RXM-M9

FTXM20M2V1B / RXM20M3V1B9 FTXM25M2V1B / RXM25M3V1B9 FTXM35M2V1B / RXM35M3V1B9 FTXM42M2V1B / RXM42M3V1B9 FTXM50M2V1B / RXM50M3V1B9 FTXM60M2V1B / RXM60M3V1B9
Cooling capacity Min. kW 1.3 1.3 1.4 1.70 1.70 1.90
  Nom. kW 2.0 2.5 3.4 4.20 5.00 6.00
  Max. kW 2.6 3.2 4.0 5.00 5.30 6.70
Heating capacity Min. kW 1.30 1.30 1.40 1.70 1.70 1.70
  Nom. kW 2.50 2.80 4.00 5.40 5.80 7.00
  Max. kW 3.50 4.70 5.20 6.00 6.50 8.00
Nominal efficiency EER   4.57 4.50 4.23 3.75 3.68 3.39
  COP   5.00 5.00 4.04 4.12 4.00 3.61
  Annual energy consumption kWh 220 280 400      
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Capacity Pdesign kW 2.00 2.50 3.40 4.20 5.00 6.00
  Energy efficiency class   A+++ A+++ A+++ A++ A++ A++
  SEER   8.53 8.52 8.51 7.50 7.33 6.90
  Annual energy consumption kWh/a 83 103 140 196 239 304
Space heating (Average climate) Capacity Pdesign kW 2.30 2.40 2.50 4.00 4.60 4.60
  Energy efficiency class   A+++ A+++ A+++ A++ A++ A+
  SCOP/A   5.10 5.10 5.10 4.60 4.60 4.30
  Annual energy consumption kWh/a 632 659 686 1,216 1,400 1,496
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.