Specifications Table for FTXJ-MW / RXJ-M

FTXJ20MV1BW / RXJ20M2V1B FTXJ20MV1BW / RXJ20M3V1B FTXJ20MV1BW / RXJ20M5V1B FTXJ25MV1BW / RXJ25M2V1B FTXJ25MV1BW / RXJ25M3V1B FTXJ25MV1BW / RXJ25M5V1B FTXJ35MV1BW / RXJ35M2V1B FTXJ35MV1BW / RXJ35M3V1B FTXJ35MV1BW / RXJ35M5V1B FTXJ50MV1BW / RXJ50MV1B
Indoor unit     FTXJ20MV1BW     FTXJ25MV1BW     FTXJ35MV1BW  
Outdoor unit     RXJ20M5V1B     RXJ25M5V1B     RXJ35M5V1B  
Cooling capacity Min. kW   1.30     0.90     0.90    
  Min. Btu/h   4,400     3,100     3,100    
  Min. kcal/h   1,120     770     770    
  Nom. kW 2.3 2.30 2.30 2.4 2.40 2.40 3.5 3.50 3.50 4.80
  Nom. Btu/h   7,848     8,189     11,942    
  Nom. kcal/h   1,978     2,064     3,009    
  Max. kW   2.80     3.30     4.10    
  Max. Btu/h   9,500     11,300     14,000    
  Max. kcal/h   2,410     2,840     3,530    
Heating capacity Min. kW   1.30     0.90     0.90    
  Min. Btu/h   4,400     3,100     3,100    
  Min. kcal/h   1,120     770     770    
  Nom. kW 2.5 2.50 2.5 3.2 3.20 3.2 4 4.00 4.0 5.80
  Nom. Btu/h   8,530     10,919     13,649    
  Nom. kcal/h   2,150     2,752     3,439    
  Max. kW   4.30     4.70     5.10    
  Max. Btu/h   14,600     16,000     17,400    
  Max. kcal/h   3,700     4,040     4,390    
Power input Cooling Nom. kW 0.50 0.50 0.50 0.51 0.51 0.51 0.86 0.86 0.86 1.43
  Heating Nom. kW 0.50 0.50 0.50 0.70 0.70 0.70 0.99 0.99 0.99 1.59
Nominal efficiency EER   4.64 4.64 4.64 4.73 4.73 4.73 4.09 4.09 4.09 3.35
  COP   5.00 5.00 5.00 4.57 4.57 4.57 4.04 4.04 4.04 3.65
  Annual energy consumption kWh 248 248 248 254 254 254 428 428 428 716
  Energy labeling Directive Cooling   A A A A A A A A A A
    Heating   A A A A A A A A A A
Space cooling Capacity Pdesign kW 2.30 2.30 2.3 2.40 2.40 2.4 3.50 3.50 3.5 4.80
  Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A++ A++
  SEER   8.73 8.73 8.73 8.64 8.64 8.64 7.19 7.19 7.19 7.02
  Annual energy consumption kWh/a 92 92 92 97 97 97 170 170 170 239
  A Condition (35°C - 27/19) Pdc kW 2.30 2.30 2.30 2.40 2.40 2.40 3.50 3.50 3.50 4.80
    EERd   4.64 4.64 4.64 4.73 4.73 4.73 4.09 4.09 4.09 3.35
    Power input kW 0.50 0.50 0.50 0.51 0.51 0.51 0.86 0.86 0.86 1.43
  B Condition (30°C - 27/19) Pdc kW 1.62 1.69 1.62 1.70 1.77 1.70 2.53 2.58 2.53 3.47
    EERd   7.67 6.83 7.67 7.33 6.59 7.33 5.44 5.44 5.44 5.24
    Power input kW 0.21 0.25 0.21 0.23 0.27 0.23 0.47 0.47 0.47 0.66
  C Condition (25°C - 27/19) Pdc kW 1.27 1.09 1.27 1.27 1.14 1.27 1.66 1.66 1.66 2.36
    EERd   10.69 10.96 10.69 10.55 10.90 10.55 7.88 7.88 7.88 8.64
    Power input kW 0.12 0.10 0.12 0.12 0.10 0.12 0.21 0.21 0.21 0.27
  D Condition (20°C - 27/19) Pdc kW 1.36 1.12 1.36 1.37 1.12 1.37 1.46 1.46 1.46 2.17
    EERd   14.25 14.56 14.25 14.16 14.28 14.16 13.76 13.76 13.76 12.00
    Power input kW 0.10 0.08 0.10 0.10 0.08 0.10 0.11 0.11 0.11 0.18
Space heating (Average climate) Capacity Pdesign kW 2.10 2.10 2.10 2.70 2.70 2.70 3.00 3.00 3.00 4.60
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A++ A++ A++ A+
  SCOP/A   4.61 4.60 4.61 4.60 4.60 4.60 4.60 4.60 4.60 4.28
  SCOPnet/A   4.65 4.65 4.65 4.66 4.65 4.66 4.64 4.64 4.64 4.30
  Pdh Heating capacity at -10° kW 1.80 1.80 1.80 2.18 2.18 2.18 2.61 2.61 2.61 4.16
  Annual energy consumption kWh/a 638 639 638 822 821 822 913 913 913 1,505
  Required back up heating cap at design conditions kW 0.30 0.30 0.30 0.52 0.52 0.52 0.39 0.39 0.39 0.44
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 1.68 1.68 1.68 1.95 1.95 1.95 2.56 2.56 2.56 4.12
    COPd (declared COP)   2.69 2.69 2.69 2.47 2.47 2.47 2.41 2.41 2.41 2.16
    Power input kW 0.62 0.62 0.62 0.79 0.79 0.79 1.06 1.06 1.06 1.91
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7 -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 1.87 1.86 1.87 2.31 2.39 2.31 2.64 2.64 2.64 4.19
    COPd (declared COP)   3.40 3.46 3.40 3.10 3.17 3.10 3.10 3.10 3.10 2.47
    Power input kW 0.55 0.54 0.55 0.75 0.75 0.75 0.85 0.85 0.85 1.70
  A Condition (-7°C) Pdh (declared heating cap) kW 1.87 1.86 1.87 2.31 2.39 2.31 2.64 2.64 2.64 4.19
    COPd (declared COP)   3.40 3.46 3.40 3.10 3.17 3.10 3.10 3.10 3.10 2.47
    Power input kW 0.55 0.54 0.55 0.75 0.75 0.75 0.85 0.85 0.85 1.70
  B Condition (2°C) Pdh (declared heating cap) kW 1.07 1.13 1.07 1.40 1.45 1.40 1.53 1.53 1.53 2.49
    COPd (declared COP)   4.89 4.78 4.89 4.87 4.77 4.87 4.80 4.80 4.80 4.41
    Power input kW 0.22 0.24 0.22 0.29 0.30 0.29 0.32 0.32 0.32 0.56
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 0.73 1.00 1.00 0.93 1.00 1.07 1.07 1.07 1.63
    COPd (declared COP)   5.37 5.03 5.37 5.37 5.38 5.37 5.40 5.40 5.40 5.24
    Power input kW 0.19 0.15 0.19 0.19 0.17 0.19 0.20 0.20 0.20 0.31
  D Condition (12°C) Pdh (declared heating cap) kW 0.96 0.87 0.96 0.96 0.87 0.96 0.99 0.99 0.99 1.87
    COPd (declared COP)   6.36 6.71 6.36 6.36 6.55 6.36 6.42 6.42 6.42 7.95
    Power input kW 0.15 0.13 0.15 0.15 0.13 0.15 0.15 0.15 0.15 0.24
Space heating (Warm climate) Capacity Pdesignh kW 1.07 1.07 1.07 1.40 1.40 1.40 1.53 1.53 1.53 2.49
  Energy efficiency class   A++ A+++ A++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
  SCOP   5.00 5.18 5.00 5.21 5.38 5.21 5.32 5.32 5.32 5.77
  SCOPnet   5.11 5.31 5.11 5.30 5.48 5.30 5.41 5.41 5.41 5.86
  Annual energy consumption kWh/a 300 289 300 376 365 376 403 403 403 604
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 1.68 1.68 1.68 1.95 1.95 1.95 2.56 2.56 2.56 4.12
    COPd (declared COP)   2.69 2.69 2.69 2.47 2.47 2.47 2.41 2.41 2.41 2.16
    Power input kW 0.62 0.62 0.62 0.79 0.79 0.79 1.06 1.06 1.06 1.91
  TBivalent Tbiv (bivalent temperature) °C 2 2 2 2 2 2 2 2 2 2
    Pdh (declared heating cap) kW 1.07 1.07 1.07 1.40 1.40 1.40 1.53 1.53 1.53 2.49
    COPd (declared COP)   4.89 4.89 4.89 4.87 4.87 4.87 4.80 4.80 4.80 4.41
    Power input kW 0.22 0.22 0.22 0.29 0.29 0.29 0.32 0.32 0.32 0.56
  B Condition (2°C) Pdh (declared heating cap) kW 1.07 1.13 1.07 1.40 1.45 1.40 1.53 1.53 1.53 2.49
    COPd (declared COP)   4.89 4.78 4.89 4.87 4.77 4.87 4.80 4.80 4.80 4.41
    Power input kW 0.22 0.24 0.22 0.29 0.30 0.29 0.32 0.32 0.32 0.56
  C Condition (7°C) Pdh (declared heating cap) kW 1.00 0.73 1.00 1.00 0.93 1.00 1.07 1.07 1.07 1.63
    COPd (declared COP)   5.37 5.03 5.37 5.37 5.38 5.37 5.40 5.40 5.40 5.24
    Power input kW 0.19 0.15 0.19 0.19 0.17 0.19 0.20 0.20 0.20 0.31
  D Condition (12°C) Pdh (declared heating cap) kW 0.96 0.87 0.96 0.96 0.87 0.96 0.99 0.99 0.99 1.9
    COPd (declared COP)   6.36 6.71 6.36 6.36 6.55 6.36 6.42 6.42 6.42 7.95
    Power input kW 0.15 0.13 0.15 0.15 0.13 0.15 0.15 0.15 0.15 0.24
Power consumption in other than active mode Crankcase heater mode PCK W 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
  Off mode POFF W 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
  Standby mode Cooling PSB W 1.0 1.00 1.00 1.0 1.00 1.00 1.0 1.00 1.00 1.0
    Heating PSB W   1.0     1.0     1.0    
  Thermostat-off mode PTO Cooling W   9     9     9    
      Heating W   9.0 9.0   9.0 9.0   9.0 9.0  
Pto (Thermostat off) W 9.0     9.0     9.0     9.0
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No No No No No
Warm season included No Yes Yes No Yes Yes No Yes Yes No
Ecolabel logo   No No   No No   No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61 61 61 61 61 63 63 63 63
  Sound power level indoor Cooling Nom. dBA 54 54 54 54 54 54 59 59 59 60
Notes (0) - EER/COP according to Eurovent 2012, for use outside EU only     (0) - EER/COP according to Eurovent 2012, for use outside EU only     (0) - EER/COP according to Eurovent 2012, for use outside EU only     (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (1) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (1) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (1) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Notes_Description   1 1   1 1   1 1