FTXG20LV1BW / RXG20L2V1B |
FTXG25LV1BW / RXG25L2V1B |
FTXG35LV1BW / RXG35L2V1B |
FTXG50LV1BW / RXG50L2V1B |
Cooling capacity |
Min. |
kW |
1.3 (2) |
1.3 (2) |
1.4 (2) |
1.7 (2) |
|
Min. |
Btu/h |
4,400 (2) |
4,400 (2) |
4,800 (2) |
5,800 (2) |
|
Min. |
kcal/h |
1,120 (2) |
1,120 (2) |
1,200 (2) |
1,460 (2) |
|
Rated |
kW |
2.3 (2) |
2.4 (2) |
3.5 (2) |
4.8 (2) |
|
Rated |
Btu/h |
7,800 (2) |
8,200 (2) |
11,900 (2) |
16,400 (2) |
|
Rated |
kcal/h |
1,980 (2) |
2,060 (2) |
3,010 (2) |
4,130 (2) |
|
Max. |
kW |
2.8 (2) |
3.0 (2) |
3.8 (2) |
5.3 (2) |
|
Max. |
Btu/h |
9,500 (2) |
10,200 (2) |
13,000 (2) |
18,100 (2) |
|
Max. |
kcal/h |
2,410 (2) |
2,580 (2) |
3,270 (2) |
4,560 (2) |
Heating capacity |
Min. |
kW |
1.3 (2) |
1.3 (2) |
1.4 (2) |
1.7 (2) |
|
Min. |
Btu/h |
4,400 (2) |
4,400 (2) |
4,800 (2) |
5,800 (2) |
|
Min. |
kcal/h |
1,120 (2) |
1,120 (2) |
1,200 (2) |
1,460 (2) |
|
Rated |
kW |
2.5 (2) |
3.4 (2) |
4.0 (2) |
5.8 (2) |
|
Rated |
Btu/h |
8,500 (2) |
11,600 (2) |
13,600 (2) |
19,800 (2) |
|
Rated |
kcal/h |
2,150 (2) |
2,920 (2) |
3,440 (2) |
4,990 (2) |
|
Max. |
kW |
4.3 (2) |
4.5 (2) |
5.0 (2) |
6.5 (2) |
|
Max. |
Btu/h |
14,600 (2) |
15,400 (2) |
17,100 (2) |
22,200 (2) |
|
Max. |
kcal/h |
3,700 (2) |
3,870 (2) |
4,300 (2) |
5,590 (2) |
Power input |
Cooling |
Min. |
kW |
0.320 (2) |
0.320 (2) |
0.350 (2) |
0.370 (2) |
|
|
Nom. |
kW |
0.501 (2) |
0.523 (2) |
0.882 (2) |
1.360 (2) |
|
|
Max. |
kW |
0.760 (2) |
0.820 (2) |
1.190 (2) |
1.880 (2) |
|
Heating |
Min. |
kW |
0.310 (2) |
0.310 (2) |
0.320 (2) |
0.310 (2) |
|
|
Nom. |
kW |
0.500 (2) |
0.769 (2) |
0.985 (2) |
1.589 (2) |
|
|
Max. |
kW |
1.120 (2) |
1.320 (2) |
1.490 (2) |
2.490 (2) |
Nominal efficiency |
EER |
|
4.59 (1) |
4.59 (1) |
3.97 (1) |
3.53 (1) |
|
COP |
|
5.00 (1) |
4.42 (1) |
4.06 (1) |
3.65 (1) |
|
Annual energy consumption |
kWh |
250.5 |
261.5 |
441 |
680 |
|
Energy labeling Directive |
Cooling |
|
A |
A |
A |
A |
|
|
Heating |
|
A |
A |
A |
A |
Space cooling |
Capacity |
Pdesign |
kW |
2.30 |
2.40 |
3.50 |
4.80 |
|
Energy efficiency class |
|
A+++ |
A+++ |
A++ |
A++ |
|
SEER |
|
8.52 |
8.50 |
7.00 |
6.70 |
|
Annual energy consumption |
kWh/a |
94 |
99 |
175 |
251 |
|
A Condition (35°C - 27/19) |
Pdc |
kW |
2.30 |
2.40 |
3.50 |
4.80 |
|
|
EERd |
|
4.50 |
4.59 |
3.97 |
3.41 |
|
|
Power input |
kW |
0.51 |
0.52 |
0.88 |
1.41 |
|
B Condition (30°C - 27/19) |
Pdc |
kW |
1.62 |
1.70 |
2.53 |
3.37 |
|
|
EERd |
|
7.59 |
7.26 |
5.39 |
5.46 |
|
|
Power input |
kW |
0.21 |
0.23 |
0.47 |
0.62 |
|
C Condition (25°C - 27/19) |
Pdc |
kW |
1.23 |
1.23 |
1.66 |
2.19 |
|
|
EERd |
|
10.28 |
10.15 |
7.58 |
7.83 |
|
|
Power input |
kW |
0.12 |
0.12 |
0.22 |
0.28 |
|
D Condition (20°C - 27/19) |
Pdc |
kW |
1.26 |
1.27 |
1.27 |
1.71 |
|
|
EERd |
|
13.70 |
13.62 |
13.10 |
10.23 |
|
|
Power input |
kW |
0.09 |
0.09 |
0.10 |
0.17 |
Space heating (Average climate) |
Capacity |
Pdesign |
kW |
2.10 |
2.70 |
3.00 |
4.60 |
|
Energy efficiency class |
|
A++ |
A++ |
A++ |
A+ |
|
SCOP/A |
|
4.60 |
4.60 |
4.60 |
4.24 |
|
Annual energy consumption |
kWh/a |
639 |
821 |
913 |
1,519 |
|
Required back up heating cap at design conditions |
kW |
0.30 |
0.52 |
0.39 |
0.78 |
|
TOL |
Tol (temperature operating limit) |
°C |
-15 |
-15 |
-15 |
-15 |
|
|
Pdh (declared heating cap) |
kW |
1.68 |
1.95 |
2.56 |
3.19 |
|
|
COPd (declared COP) |
|
2.69 |
2.47 |
2.41 |
1.49 |
|
|
Power input |
kW |
0.62 |
0.79 |
1.06 |
2.14 |
|
TBivalent |
Tbiv (bivalent temperature) |
°C |
-7 |
-7 |
-7 |
-7 |
|
|
Pdh (declared heating cap) |
kW |
1.87 |
2.31 |
2.64 |
4.19 |
|
|
COPd (declared COP) |
|
3.40 |
3.30 |
3.06 |
2.43 |
|
|
Power input |
kW |
0.55 |
0.70 |
0.86 |
1.72 |
|
A Condition (-7°C) |
Pdh (declared heating cap) |
kW |
1.87 |
2.31 |
2.64 |
4.19 |
|
|
COPd (declared COP) |
|
3.40 |
3.30 |
3.06 |
2.43 |
|
|
Power input |
kW |
0.55 |
0.70 |
0.86 |
1.72 |
|
B Condition (2°C) |
Pdh (declared heating cap) |
kW |
1.07 |
1.40 |
1.53 |
2.49 |
|
|
COPd (declared COP) |
|
4.66 |
4.65 |
4.68 |
4.49 |
|
|
Power input |
kW |
0.23 |
0.30 |
0.33 |
0.55 |
|
C Condition (7°C) |
Pdh (declared heating cap) |
kW |
0.92 |
1.06 |
1.13 |
1.63 |
|
|
COPd (declared COP) |
|
5.68 |
5.71 |
5.67 |
5.37 |
|
|
Power input |
kW |
0.16 |
0.19 |
0.20 |
0.30 |
|
D Condition (12°C) |
Pdh (declared heating cap) |
kW |
1.03 |
1.03 |
1.06 |
1.08 |
|
|
COPd (declared COP) |
|
6.80 |
6.80 |
6.80 |
5.97 |
|
|
Power input |
kW |
0.15 |
0.15 |
0.16 |
0.18 |
Power consumption in other than active mode |
Crankcase heater mode |
PCK |
W |
0.0 |
0.0 |
0.0 |
0.0 |
|
Off mode |
POFF |
W |
1.0 |
1.0 |
1.0 |
1.0 |
|
Standby mode |
Cooling |
PSB |
W |
1.0 |
1.0 |
1.0 |
1.0 |
Pto (Thermostat off) |
W |
9.0 |
9.0 |
9.0 |
8.0 |
Cooling |
Cdc (Degradation cooling) |
|
0.25 |
0.25 |
0.25 |
0.25 |
Heating |
Cdh (Degradation heating) |
|
0.25 |
0.25 |
0.25 |
0.25 |
Cooling function included |
Yes |
Yes |
Yes |
Yes |
Heating function included |
Yes |
Yes |
Yes |
Yes |
Average climate included |
Yes |
Yes |
Yes |
Yes |
Cold season included |
No |
No |
No |
No |
Warm season included |
No |
No |
No |
No |
Ecolabel logo |
No |
No |
No |
No |
Piping connections |
Drain |
OD |
mm |
18 |
18.0 |
18.0 |
18.0 |
|
Gas |
OD |
mm |
9.5 |
9.5 |
9.5 |
12.7 |
|
Heat insulation |
|
Both liquid and gas pipes |
Both liquid and gas pipes |
Both liquid and gas pipes |
Both liquid and gas pipes |
|
Liquid |
OD |
mm |
6.35 |
6.35 |
6.35 |
6.35 |
Current |
Nominal running current (RLA) - 50Hz |
Cooling |
A |
2.8 (6), 2.7 (7), 2.6 (8) |
2.9 (6), 2.8 (7), 2.7 (8) |
5.0 (6), 4.8 (7), 4.6 (8) |
6.5 (6), 6.2 (7), 5.9 (8) |
|
|
Heating |
A |
2.8 (6), 2.7 (7), 2.6 (8) |
4.4 (6), 4.2 (7), 4.0 (8) |
5.5 (6), 5.3 (7), 5.1 (8) |
7.4 (6), 7.1 (7), 6.8 (8) |
Notes |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
(1) - EER/COP according to Eurovent 2012, for use outside EU only |
|
(2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
(2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
(2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
(2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load |
|
(4) - SL: The silent fan level of the air flow rate setting |
(4) - SL: The silent fan level of the air flow rate setting |
(4) - SL: The silent fan level of the air flow rate setting |
(4) - SL: The silent fan level of the air flow rate setting |
|
(6) - 220V |
(6) - 220V |
(6) - 220V |
(6) - 220V |
|
(7) - 230V |
(7) - 230V |
(7) - 230V |
(7) - 230V |
|
(8) - 240V |
(8) - 240V |
(8) - 240V |
(8) - 240V |