FTXG25LV1BW / RXG25L2V1B FTXG20LV1BW / RXG20L2V1B FTXG35LV1BW / RXG35L2V1B FTXG50LV1BW / RXG50L2V1B
Poff (Off mode) W 1.0 1.0 1.0 1.0
Cooling Psb (Standby mode cooling) W 1.0 1.0 1.0 1.0
  Cdc (Degradation cooling) 0.25 0.25 0.25 0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 2.40 2.30 3.50 4.80
    Annual energy consumption kWh 99 94 175 251
    Energy efficiency class 8.50 8.52 7.00 6.70
    D Condition (20°C - 27/19) Pdc kW 1.27 1.26 1.27 1.71
      power input kW 0.09 0.09 0.10 0.17
      EERd 13.62 13.70 13.10 10.23
    C Condition (25°C - 27/19) power input kW 0.12 0.12 0.22 0.28
      Pdc kW 1.23 1.23 1.66 2.19
      EERd 10.15 10.28 7.58 7.83
    A Condition (35°C - 27/19) power input kW 0.52 0.51 0.88 1.41
      Pdc kW 2.40 2.30 3.50 4.80
      EERd 4.59 4.50 3.97 3.41
    B Condition (30°C - 27/19) Pdc kW 1.70 1.62 2.53 3.37
      power input kW 0.23 0.21 0.47 0.62
      EERd 7.26 7.59 5.39 5.46
  Heating (Average climate) Annual energy consumption kWh 821 639 913 1,519
    Pdesign kW 2.70 2.10 3.00 4.60
    Required back up heating cap at design conditions kW 0.52 0.30 0.39 0.78
    SCOP/A A++ A++ A++ A+
    TBivalent Pdh (declared heating cap) kW 2.31 1.87 2.64 4.19
      Power input kW 0.70 0.55 0.86 1.72
      Tbiv (bivalent temperature) °C -7 -7 -7 -7
      COPd (declared COP) 3.30 3.40 3.06 2.43
    C Condition (7°C) Pdh (declared heating cap) kW 1.06 0.92 1.13 1.63
      Power input kW 0.19 0.16 0.20 0.30
      COPd (declared COP) 5.71 5.68 5.67 5.37
    TOL Tol (temperature operating limit) °C -15 -15 -15 -15
      Pdh (declared heating cap) kW 1.95 1.68 2.56 3.19
      Power input kW 0.79 0.62 1.06 2.14
      COPd (declared COP) 2.47 2.69 2.41 1.49
    A Condition (-7°C) Pdh (declared heating cap) kW 2.31 1.87 2.64 4.19
      Power input kW 0.70 0.55 0.86 1.72
      COPd (declared COP) 3.30 3.40 3.06 2.43
    D Condition (12°C) Pdh (declared heating cap) kW 1.03 1.03 1.06 1.08
      Power input kW 0.15 0.15 0.16 0.18
      COPd (declared COP) 6.80 6.80 6.80 5.97
    B Condition (2°C) Power input kW 0.30 0.23 0.33 0.55
      Pdh (declared heating cap) kW 1.40 1.07 1.53 2.49
      COPd (declared COP) 4.65 4.66 4.68 4.49
Cooling capacity Min. kW 1.3 (2) 1.3 (2) 1.4 (2) 1.7 (2)
  Rated Btu/h 8,200 (2) 7,800 (2) 11,900 (2) 16,400 (2)
  Max. kW 3.0 (2) 2.8 (2) 3.8 (2) 5.3 (2)
  Min. kcal/h 1,120 (2) 1,120 (2) 1,200 (2) 1,460 (2)
  Min. Btu/h 4,400 (2) 4,400 (2) 4,800 (2) 5,800 (2)
  Rated kcal/h 2,060 (2) 1,980 (2) 3,010 (2) 4,130 (2)
  Max. Btu/h 10,200 (2) 9,500 (2) 13,000 (2) 18,100 (2)
  Rated kW 2.4 (2) 2.3 (2) 3.5 (2) 4.8 (2)
  Max. kcal/h 2,580 (2) 2,410 (2) 3,270 (2) 4,560 (2)
Pck (Crankcase heater mode) W 0.0 0.0 0.0 0.0
Nominal efficiency Annual energy consumption kWh 261.5 (0.000) 250.5 (0.000) 441 (0.000) 680 (0.000)
  Energy labeling Directive Heating A A A A
  COP 4.59 (1) 4.59 (1) 3.97 (1) 3.53 (1)
Heating Cdh (Degradation heating) 0.25 0.25 0.25 0.25
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 9.5 12.7
  Drain OD mm 18.0 18 18.0 18.0
  Heat insulation Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Heating capacity Min. Btu/h 4,400 (2) 4,400 (2) 4,800 (2) 5,800 (2)
  Rated Btu/h 11,600 (2) 8,500 (2) 13,600 (2) 19,800 (2)
  Max. kcal/h 3,870 (2) 3,700 (2) 4,300 (2) 5,590 (2)
  Rated kcal/h 2,920 (2) 2,150 (2) 3,440 (2) 4,990 (2)
  Rated kW 3.4 (2) 2.5 (2) 4.0 (2) 5.8 (2)
  Max. Btu/h 15,400 (2) 14,600 (2) 17,100 (2) 22,200 (2)
  Min. kW 1.3 (2) 1.3 (2) 1.4 (2) 1.7 (2)
  Min. kcal/h 1,120 (2) 1,120 (2) 1,200 (2) 1,460 (2)
  Max. kW 4.5 (2) 4.3 (2) 5.0 (2) 6.5 (2)
Pto (Thermostat off) W 9.0 9.0 9.0 8.0
Power input Cooling Min. kW 0.320 (2) 0.320 (2) 0.350 (2) 0.370 (2)
    Nom. kW 0.523 (2) 0.501 (2) 0.882 (2) 1.360 (2)
    Max. kW 0.820 (2) 0.760 (2) 1.190 (2) 1.880 (2)
  Heating Max. kW 1.320 (2) 1.120 (2) 1.490 (2) 2.490 (2)
    Min. kW 0.310 (2) 0.310 (2) 0.320 (2) 0.310 (2)
    Nom. kW 0.769 (2) 0.500 (2) 0.985 (2) 1.589 (2)
Cold season included Yes Yes Yes Yes
Current Nominal running current (RLA) - 50Hz Heating A 4.4 (6), 4.2 (7), 4.0 (8) 2.8 (6), 2.7 (7), 2.6 (8) 5.5 (6), 5.3 (7), 5.1 (8) 7.4 (6), 7.1 (7), 6.8 (8)
    Cooling A 2.9 (6), 2.8 (7), 2.7 (8) 2.8 (6), 2.7 (7), 2.6 (8) 5.0 (6), 4.8 (7), 4.6 (8) 6.5 (6), 6.2 (7), 5.9 (8)
Notes EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  SL: The silent fan level of the air flow rate setting SL: The silent fan level of the air flow rate setting SL: The silent fan level of the air flow rate setting SL: The silent fan level of the air flow rate setting
  220V 220V 220V 220V
  230V 230V 230V 230V
  240V 240V 240V 240V