Specifications Table for FFA-A9 / RXM-R

FFA25A2VEB9 / RXM25R5V1B FFA35A2VEB9 / RXM35R5V1B FFA50A2VEB9 / RXM50R2V1B FFA60A2VEB9 / RXM60R2V1B
Cooling capacity Nom. kW 2.50 3.40 5.00 5.70
Heating capacity Nom. kW 3.20 4.20 5.80 7.00
Nominal efficiency EER   4.57 3.81 3.24 3.05
  COP   3.90 3.50 3.49 3.41
  Annual energy consumption kWh 273 446 772 934
  Energy labeling Directive Cooling   A A A B
    Heating   A B B B
Space cooling Energy efficiency class   A++ A++ A+ A+
  Capacity Pdesign kW 2.50 3.40 5.00 5.70
  SEER   6.17 6.38 5.98 5.76
  Annual energy consumption kWh/a 142 186 292 347
Space heating (Average climate) Energy efficiency class   A+ A+ A A+
  Capacity Pdesign kW 2.31 3.10 3.84 3.96
  SCOP/A   4.24 4.10 3.90 4.04
  Annual energy consumption kWh/a 762 1,058 1,377 1,372
Notes (1) - See separate drawing for electrical data (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - See separate drawing for operation range (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data